LUMINEX® 100/200™ 支持服务

快捷提示

Luminex® 200™ 的固件检查

Luminex® 200™ 的固件检查

 
提示如何在Luminex® 200™ 仪器上检查固件

 

Luminex® 200™ 输入证书密钥

Luminex® 200™ 输入证书密钥

 
演示如何将密钥导入Luminex® 200™仪器的xPONENT®软件里

 

xPONENT® 3.1 转换文件

xPONENT® 3.1 转换文件

 
演示如何为您的Luminex® 200™ 将IS2.3软件的文件转换到xPONENT® 3.1软件里

故障排除

Luminex® 200™ 漏液故障排除

Luminex® 200™ 漏液故障排除

 
Luminex® 200™ 排除漏液故障的教学视频
 
 

 

Luminex® 200™ 读数问题的故障排除

Luminex® 200™ 读数问题的故障排除

 
本视频演示Luminex® 200™设备读数故障排除的步骤,请让技术支持人员引导您通过执行这些步骤排除故障,使仪器重新工作正常

 

Luminex® 200™ SDS Error Alarm Troubleshooting

This troubleshooting video informs Luminex® 200™ users on how to detect the audible alarm and fault LED on the Luminex SDS, how to troubleshoot the issue, how to drain the SDS and how to refill it.

维护

调整标本探针高度

Luminex® 200™ Probe Height Adjustment

 
本视频简介将分步演示如何调整Luminex® 200™设备的标本探针高度

 

绕过标本探针

Luminex® 200™: Sample Probe Bypass

 
本视频将演示如何绕过标本探针以检查探针是否有问题
 

 

Replacing the XYP Air Intake Filter

Luminex® 200™: Replacing the XYP Air Intake Filter

 
Why should you replace the air intake filter on the XY Platform? The air intake filter keeps dust and large particles out of the XY Platform and should be replaced as part of the semi-annual maintenance routine.

Cleaning the Analyzer Vent Filter

Luminex® 200™: Cleaning the Analyzer Vent Filter

 
Let’s take a look at the procedure for removing, cleaning, and replacing the vent filter on the Luminex 200 analyzer as part of the semi-annual maintenance schedule.

Luminex 200: Clean Exterior Surfaces

Luminex® 200™: Clean Exterior Surfaces

 
In this video, we will go over how to clean the exterior surfaces of the Luminex 200. This routine is part of the monthly maintenance schedule to keep the Luminex 200 clean and sterile.
 

Luminex 200 Visual Inspection

Luminex® 200™: Visual Inspection

 
Let’s take a look at the procedure of performing a visual inspection of the Luminex 200 Instrument. This routine is part of the weekly maintenance schedule to keep the system clean and to help identify potential issues.

Luminex 200 Syringe Seal Replacement

Luminex® 200™: Syringe Seal Replacement

 
Replacing the seal will prevent leaks or pressure loss in the fluidics system. This preventative maintenance procedure is to be used if the seal is not performing properly.

Replacing the Analyzer Air Intake Filter

 Luminex® 200™: Replacing the Analyzer Air Intake Filter

 
The intake air filter needs to be replaced every six months to keep the fluidics bay sterile and clean of particles that build up on the filter over time.
 

Luminex 200 Startup & Shutdown Procedure

Luminex® 200™: Startup & Shutdown Procedure

 
Following the startup and shutdown daily maintenance routines help ensure accurate test results by properly cleaning and maintaining the instrument.
 

Replacing the Sheath Filter

Luminex® 200™: Replacing the Sheath Filter

 
Keeping the sheath filter clean helps ensure accurate test results by keeping the fluidics system clean of particles that buildup on the filter. The filter needs to be replaced annually.

Luminex 200 Fuse Replacement

Luminex® 200™: Fuse Replacement

 
Let’s take a look at the procedure for removing and replacing the fuses on the Luminex 200. This process is only required if a fuse is tripped.
 

Flush the Luminex 200 System

Luminex® 200™: Flush the System

 
Flushing the system ensures that all the fluidics lines and the chamber in the Luminex 200 are clean and debris free. It is important to flush the system once per week.

使用

Luminex® 200™: 将CON1作为被测样品

Luminex® 200™: 将CON1作为被测样品

 
本教学视频将指导您如何将CON1作为被测样品

 

Luminex® 200™ xPONENT® 3.1 软件升级指导

Luminex® 200™ xPONENT® 3.1 软件升级指导

 
视频演示如何从IS2.3 升级到xPONENT® 3.1

加强清洗流程

加强清洗流程

 
加强清洗包括四个步骤,能排除如校准或验证失败,标本探针或仪器堵塞等各种问题

清洗并设定标本探针的高度

清洗并设定标本探针的高度

 
有好几种原因要清洗标本探针和设定针的高度
 

校准/验证

校准/验证

 
对Luminex® 200™ 进行月保养或者故障排除时,应该校准和验证以确定仪器正常