Customer Center
Login | Register

xMAP® Flavivirus Serology Panel (xMAP® FSP)

xMAP® Flavivirus Serology Panel (xMAP® FSP)

Multiplexed serological assays to detect IgG and IgM levels

There is a critical need for a better Zika testing method, one that can assess if a Zika positive result may be due to cross-reactivity from exposure to another flavivirus and also provides information to determine how flavivirus status affects immunity to vaccines and subsequent exposures. Ampersand Biosciences has developed a commercial multiplex serological assay on the Luminex platform, the xMAP® Flavivirus Serology Panel (xMAP® FSP), that can determine levels of IgG and IgM to 13 flavivirus antigens, along with chikungunya, in serum or plasma samples.

 

xMAP Flavivirus Serology Panel (xMAP FSP) provides:

 

  • Testing using low sample volume
  • Results in 3 hours
  • A comprehensive picture of flavivirus status, including both VLP and NS1 antigen reactivity to Zika
  • Highly reproducible results
  • Profiling of IgG and IgM separately

 

 

xMAP Flavivirus Serology Panel (xMAP FSP) has three convenient configuration options:

 

Kit IgG Wells IgM Wells Part Number
xMAP® Flavivirus Serology Panel 1-1 48 48 MP001-1
xMAP® Flavivirus Serology Panel 1-2 96 N/A MP001-2
xMAP® Flavivirus Serology Panel 1-3 96 96 MP001-3

 

 

Each xMAP FSP kit contains:

  • Flavivirus Serology Panel 1 Beads
  • Protein G Magnetic Beads*
  • Serology Panel IgG Detection
  • Serology Panel IgM Detection*
  • Flavivirus Serology Panel 1 Control 1
  • Flavivirus Serology Panel 1 Control 2
  • Flavivirus Serology Panel 1 Control 3
  • Serology Panel Sample Dilution Buffer 1
  • Serology Panel Assay Buffer 1 (10X)
  • 96-Well Round Bottom Plate (For IgG Depletion)*
  • 96-Well Flat Bottom Plate (For Luminex Assay)
  • Plate Seals

 

*xMAP Flavivirus Serology Panel 1-1 & 1-3 Only

Workflow:

 

Step 1

Step 1

Sample Preparation
30 minutes
(Pretreat IgM only)

Step 2

Step 2

Incubation
60 minutes

Step 3

Step 3

Wash
5 minutes

 

 

Step 4

Step 4

Add Reporter/Incubation
30 minutes

Step 5

Step 5

Wash
5 minutes

Step 6

Step 6

Detection
<1 minute/sample

 

Ordering Information

 

Luminex Online Order Management
Email: [email protected]
Phone: 1-512-336-3550
Toll Free: 1-866-401-5450
Fax: 1-512-219-0544
Fax (Europe, Middle East, India, Asia): +31 (0)73 800 1998

This product is for Research Use Only, not for use in Diagnostic procedures. Please contact Luminex at [email protected] to obtain the appropriate product information for your country of residence.