Luminex Home xMap Technology
Technologies Products Applications Partners Support Company Contact
Home > RVP > xTAG Respiratory Viral Panel Overview
Email This Page
Print This Page
 

Luminex's xTAG® Respiratory Viral Panel (RVP) is a diagnostic test for the detection of multiple viral strains and subtypes. The test was designed to allow better decision-making in patient management and to limit the spread of infection, and therefore has value in both clinical settings and as a surveillance tool.

Luminex worked with a team of leading virologists and infectious disease specialists -- including James Mahony, Ph.D., of St. Joseph’s Hospital in Hamilton, Ontario -- to design a respiratory viral panel that detects the most common strains of respiratory viruses and subtypes, including respiratory syncytial virus (RSV), influenza A and adenovirus, among others.

xTAG® RVP was developed using Luminex’s Universal Array – a proprietary solution-based microarray capable of combining any set of 100 single DNA tests and performing them simultaneously in a single reaction, which operates on the Luminex xMAP® system, a well-established bioassay detection platform that uses lasers to read color-coded microspheres that attach to specific nucleic acid sequences.

xTAG® RVP Targets - U.S. IVD Test (FDA Cleared)
*For In Vitro Diagnostic Use

Viral Family Viral Subtype
Respiratory Syncytial Virus (RSV) A
B
Influenza A Non-specific Influenza A
H1
H3
Influenza B
Parainfluenza 1
Parainfluenza 2
Parainfluenza 3
Metapneumovirus
Rhinovirus
Adenovirus
MS-2 Bacteriophage Internal Control
Lambdaphage Positive Control
For product details refer to the package inserts on the xTAG® RVP CD.
xTAG®
 RVP catalogue numbers:  96 Test Kit I019C0111, CD:  S019-0116

xTAG® RVP Targets - Outside the U.S. (CE Marked)
*European Union - For In Vitro Diagnostic Use

Viral Family Viral Subtype
Respiratory Syncytial Virus (RSV) A
B
Corona Virus NL63
Corona Virus 229E
Corona Virus OC43
Corona Virus HKU1
SARS
Influenza A Non-specific Influenza A
H1
H3
H5
Influenza B
Parainfluenza 1
Parainfluenza 2
Parainfluenza 3
Parainfluenza 4
Metapneumovirus
Rhinovirus / Enterovirus
Adenovirus
MS-2 Bacteriophage Internal Control
Lambdaphage Positive Control
How xTAG® RVP Works
xTAG® RVP vs. The Competition
xTAG® RVP Supporting Information

For information on xTAG® RVP, call toll-free at 1-800-593-2370
or email at customerservice@luminexcorp.com

Home 
Overview 
Technology 
Supporting Information 
Contact & Ordering

MSDS
xTAG 10x Wash Buffer 
xTAG RVP TSPE Mix 
xTAG RVP Bead Mix 
xTAG RVP PCR Mix 

Home  |  Technology  |  Products  |  Applications  |  Partners  |  Support  |  Company  |  Contact

©2010 Luminex Corporation  |  Terms of Use  |  Disclaimer  |  Privacy Policy  |  Site Map